Twin Wall

Acessories

Gas Testing Component

Article Code: 108

Print

The Twin Wall Gas Testing Component is the fundamental component for the testing and analysis of flue gases in a Chimney System in accordance with the requirements of UNI EN 1856-1. It is placed above a 90° or 135° Tee, at a distance equal to three times the internal diameter, in accordance with the requirements of Article 7.9 of the Presidential Decree 1391.

Inner Wall: Stainless Steel 316L BA (EN 1.4404 - L50) 0.5 mm thick.

Outer Wall: Stainless Steel 304 BA (EN 1.4301 - L20) thickness 0.5 mm or Copper 0.6 mm thick.

Insulation: Rock wool, thickness 25 mm, density 90 kg / mc.

Welding: longitudinal TIG process for the fusion of adjoining pieces, without filler.

Belling: cold moulding, done with a mould and counter mould hydraulic expansion system ensuring calibrated joints with a tolerance of +/- 2mm.

Accessories: triple lip silicone gasket to ensure the joint is sealed; locking band to secure the joint and ensure the continuity of the system.

Collection, testing and analysis of the products resulting from the combustion of gas, wood-burning or multi-fuel generators.

For the designation of the chimney system according to UNI EN 1856-1 the following is allowed:

operation:
- Dry (D)
- Wet (W)

pressures:
- Positive (P1 = 200 Pa)
- Negative (N1 = 40 Pa).

Operating temperatures:
- ≤ 200 ° C with silicone gasket and P1 = 200 Pa

- ≤ 600° C without silicone gasket and N1 = 40 Pa

Dimensione 316 - 304 316 - Rame
Ø 80 € 184,09 € 227,87
Ø 100 € 200,19 € 250,68
Ø 130 € 224,87 € 285,22
Ø 150 € 241,44 € 308,49
Ø 180 € 266,79 € 343,77
Ø 200 € 283,12 € 366,88
Ø 250 € 329,62 € 431,27
Ø 300 € 378,71 € 498,24
Ø 350 € 423,39 € 559,92
Ø 400 € 468,74 € 622,33